Product Description
API 610 (BB2) RADIAL SPLIT Heavy Duty Process Pump
Design Criteria
Applicable codes and standards: APl610
Capacity: 5-5,000m3/h
Head: -350m
Temperature : -80-+450'C
Pressure: HOO/HDD·C -5Mpa
HOO-G/HOO-CG -lOMpa
Application
Petroleum Refining, Petrochemical, Coal Chemical, Natural Gas Industry, Nuclear Power ,etc,
Typical application:
Ethylene unit quench oil pump, chilling water pump, propylene fractionator reflux pump, pan oil pump, etc.
Ammonia plant decarburization pump, hydraulic turbine.etc
Coal chemical: schwarze pump, circulation pump for lock hopper
Others: cooling water circulation pump for FPSO, cooling water for nuclear power.etc.
HOO serial is suitable for pumping liquid mediums which are clean or containing particles, low or high temperature, high pressure, neutral or corrosive, and etc.
Product Overview
Horizontal, radially split. single stage, double suction. between- bearings centrifugal pump which is designed for heavy duty unit, with simple and reliable structure, stable operation,
convenient maintenance, long service life.
Impeller. Single or double suction, without asial force. Double suction impeller could extend the bearing life when operating in high pressure and have good cavitation-resistance.
Casing: Axial force is balanced by double volute type structure. Temperature deformation is balanced by centreline-mounted.
Casing cover: Rigid design, high pressure-resistance
Bearing: Self-lubricating antifriction bearing, sliding bearingor forced lubricating bearing are available by different rate power, which could guarantee the safety and reliable operation
Reviews